adaptive: the oscillation lock and the cooldown suppress the io_uring error-rate safety revert #1145
Description
Found while reviewing PR #1128 (lane L17). Pre-existing on main (a5fb8f1); not introduced by #1128 and not fixed there. Refs #886.
Summary
controller.evaluate returns at the oscillation-lock check and at the cooldown check before it reaches the io_uring error-rate safety revert. While either holds, a faulting io_uring stays the active engine. The lock is 5 minutes, and it is set precisely by the sequence an erroring io_uring produces (promote, error revert, promote again), so the controller holds the faulty engine for the longest stretches in the case the revert exists for.
Where (main a5fb8f1, internal/adaptive/controller.go)
:154if c.state.locked && now.Before(c.state.lockUntil) { return false }:162if ... now.Sub(c.state.lastSwitch) < c.cooldown { return false }:182-189the always-activesnap.ErrorRate > c.errorRevertRaterevert, reached only after both.recordSwitch(:301-328): 3 switches within 5 minutes setlockedandlockUntil = now + 5 min.
The comment at :175-182 already argues that the safety revert must not wait behind the standby-build backoff ("a backoff over it would leave an erroring engine serving for as long as standbyBuildBackoffMax"); the same argument holds for the lock and the cooldown, and they were not given the same treatment.
Scenario (default epoll start, 64 connections on 2 workers: 32 conns/worker, over the 24 up-threshold)
- The controller promotes to io_uring (sustained high load).
- io_uring faults; the error-rate revert fires (cooldown permitting) and the controller returns to epoll.
- After the 30 s cooldown
evaluateUppromotes again (cpw is still 32). That is the third switch within 5 minutes, sorecordSwitchlocks switches for 5 minutes with io_uring active. - Until the lock expires the safety revert cannot run.
Simulation (reviewer's scenario test, TestReviewLockHoldsAFaultyIOUring, mocks only)
Production cooldown (30 s), 1 s ticks, loadDownRevert = false, 64 connections on 2 workers, an io_uring that fails 50% of its requests whenever it is active, 30 simulated minutes, recordSwitch called on every recommended switch as performSwitch does:
- 15 switches;
- io_uring active 1042 s of 1800 s;
- 892 s of those under the oscillation lock.
Relation to #1128's four test failures
TestReverseTransplant, TestReverseTransplantAsync, TestBidirectionalFlap, TestBidirectionalFlapAsync failed 0/10 at --cpus 2 because 64 conns on 2 workers are 32 conns/worker and the controller promoted back to io_uring (and logged oscillation detected) after each forced revert. This issue is the production form of that mechanism: the same re-promotion at cpw 32, with the lock turning it into a 5-minute stay on the engine that was just reverted. The tests were fixed in #1128 by turning the conns-per-worker policy off in the ForceSwitch-only helper (they test transplants, not the policy); the policy gap is this issue.
Proposed fix direction (for the maintainer to choose)
- Let the error-rate revert bypass the lock and the cooldown, as it already bypasses the standby-build backoff: move the
snap.ErrorRate > errorRevertRatecheck above the lock and cooldown returns (theSamplecall sits after these two returns today, so a revert above them needs the sample taken earlier too; the delta-window comment at:166-170applies, and the first sample after a long lock spans the whole lock). The revert then also becomes a switch that counts toward the lock; decide whether a revert should extend the lock (probably not: the lock exists to stop a flap, and a faulting engine is not a flap). - And/or, after an error revert, hold
evaluateUpoff for longer than the cooldown (a back-off on re-promotion to an engine that just faulted, for example doubling per consecutive error revert, reset after a quiet period), so the controller does not return to the faulty engine every 30 s. - Tests: the scenario as a regression test (assert io_uring is active for far less than 1042 s and never under the lock), plus a unit test that the revert fires with
lockedset.
Interacts with the 3-fault floor of #1128 (886 item 29): the floor makes the revert blind to low traffic that fails entirely (error_rate_floor_lowtraffic_886_linux_test.go pins it); both concern whether the safety revert can be relied on. Worth deciding together.
Risk
Behaviour change in the controller's safety path (switching). LOW code size; needs the maintainer's decision on 1 vs 2.