Skip to content

Support Smart Alarm Wireless Indoor Cameras (scout / suspected device type 21) #1186

Open

Description

@mschlottfeld

The simplisafe-python library does not recognize the scout camera model identifier or device type 21, producing repeated errors when the Home Assistant SimpliSafe integration initializes.

Unknown camera type: scout
Unknown device type: 21

Both errors appear to be associated with SimpliSafe Smart Alarm Wireless Indoor Cameras.

Environment

Home Assistant Core: 2026.10.0
Installation: Home Assistant OS
Integration: Built-in SimpliSafe
Python dependency: simplisafe-python==2026.06.0
SimpliSafe system: V3
Cameras: Four Smart Alarm Wireless Indoor Cameras, one outdoor camera, and one video doorbell

Confirmed observations
All four Smart Alarm Wireless Indoor Cameras are registered in Home Assistant.
Each indoor camera's device information identifies its model as Camera (scout).
The library's camera-model mapping does not include scout, resulting in CameraTypes.UNKNOWN.
The library's device-type enumeration does not define numeric type 21, resulting in DeviceTypes.UNKNOWN.
The Home Assistant diagnostics export identifies four corresponding indoor camera locations with sensor type: 99, the library's fallback value for unrecognized device types.
Each indoor camera has a motion event entity in Home Assistant. However, the event entity displayed Unknown when inspected, and successful motion-event delivery has not been independently verified.
The outdoor camera and video doorbell are recognized without the same camera-model error.
Relationship between the errors
The four unrecognized sensor entries correspond to the four Smart Alarm Wireless Indoor Cameras.
This strongly suggests that device type 21 represents these cameras, but the diagnostics export converts unrecognized device types to 99, so it does not preserve the original raw numeric identifiers.
The association should therefore be verified against the raw API data before assigning a definitive device-type name.
Relevant source code
simplipy/device/camera.py

The MODEL_TO_TYPE mapping recognizes:
SS001
SS002
SS003
SSOBCM4

It does not recognize scout.

simplipy/device/init.py

The DeviceTypes enumeration defines:

MOTION_V2 = 20
OUTDOOR_ALARM_SECURITY_BELL_BOX = 22
But does not define device type 21.
simplipy/system/v3.py

Camera objects and sensor objects are constructed separately, which may explain why the same physical camera appears in both inventories.

Expected behavior

Smart Alarm Wireless Indoor Cameras should be recognized by their proper identifiers without generating unknown-type errors.
Existing alarm, sensor, and event behavior should remain unchanged.

Suggested correction
Investigate adding scout to MODEL_TO_TYPE, mapping it to CameraTypes.CAMERA if its behavior is compatible.
Verify the raw device type corresponding to the Smart Alarm Wireless Indoor Camera.
If type 21 is confirmed, add a distinct device-type enumeration member rather than mapping it to an unrelated existing sensor type.
Add regression tests for both identifiers.
Preserve compatibility with existing SimpliSafe V3 devices.
Additional information
A Home Assistant diagnostics export is available, but the full file is not attached because it contains security-system configuration and potentially sensitive identifiers.
A sanitized excerpt can be provided if needed.

Thank you for maintaining this library and considering support for these cameras!

Activity

  1. github-actions commented on Nov 9, 2026

    @github-actions

    There hasn't been any activity on this issue recently, so it has been marked as stale.
    Please make sure to update to the latest version and check if that solves the issue. Let us know if that works for you by leaving a comment.
    This issue will be closed if no further activity occurs. Thanks!

  2. added
    staleThere has not been activity on this issue or PR for some time
    on Nov 9, 2026
  3. jtmchorse commented on Nov 11, 2026

    @jtmchorse

    I opened #1198 for this. From a capture of my own system, the indoor camera shows up as model scout in the camera list and as device type 21 in the sensors list, with the same serial. The PR maps both so the "Unknown" errors go away. It doesn't add video for these cameras.

  4. mschlottfeld commented on Nov 11, 2026

    @mschlottfeld
    Author

    Thank you for taking the time to investigate this and work on a solution. I appreciate your effort and the contribution to getting these cameras properly supported!

  5. removed
    staleThere has not been activity on this issue or PR for some time
    on Nov 11, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions