APAPUMP

APAPUMP

Autonomous filtration pump controller for APA Devices pool automation · v1.3.3 · Platforms


Key Features

Pump control

  • PCF8574AT I2C relay expander (default) or direct Arduino GPIO — one constructor covers both
  • Non-blocking state machine: IDLE → STARTING → RUNNING → STOPPING
  • Safe boot: all relays start OFF regardless of previous relay or pin state
  • Manual override: FORCE_ON, FORCE_OFF, AUTO — with optional timeout or midnight auto-return
  • Extension relay outputs on PCF P4–P7 for lights or extra equipment

Scheduling and daily tracking

  • Schedule callback drives pump on/off without any external library
  • Daily runtime target with catch-up logic and optional time window
  • Midnight rollover via RTC epoch callback or 24-hour millis() fallback

Follower devices

  • UVC sanitizer — ON before pump, OFF after (configurable pre/post delay)
  • AUX device — plain follower (ozone etc.), or a heat pump in HEATER_SIMPLE / HEATER_FULL (details)
  • Solar valve — follows the solar demand, also during a scheduled run; instantly closes in manual mode

Solar heating

  • Extra runs on top of your schedule: heating (collector warmer than the pool) and cooling (pool above Max pool)
  • Absorber–pool temperature dead-band hysteresis (configurable start/stop deltas)
  • Invalid temperatures (missing sensor, DS18B20 power-on value) stop all solar logic — never acted on
  • Day/night gate for heating — a safety net for a badly placed collector sensor (why)
  • Overheat protection: collector too hot → pump ON + valve OPEN, in AUTO only and never during a pump alarm

Heater (heat pump)

  • Solar first — the heat pump waits while solar heats
  • Never heats without flow: off on any pump alarm; 10-minute minimum ON/OFF against compressor short-cycling
  • HEATER_SIMPLE (the heat pump's own thermostat regulates) or HEATER_FULL (the library is the thermostat)
  • Permit hook for a cheap-tariff input

Saved settings

  • Solar mode, Max pool, AUX/heater mode, heater target and pressure ON/OFF survive a reboot (details)

Safety alarms

  • Overcurrent — learns the pump's own normal current, alarms at × 1.5; no pump rating to enter; silent with an external contactor (details)
  • Dry-run — pressure below EMA baseline × 40% (or absolute minimum before EMA builds)
  • Overpressure — absolute hard limit at maxPressure (the filter's rated pressure); optional sudden-rise alarm
  • Pressure monitoring can be switched off at runtime — setPressureEnabled(false) for installations without a pressure sensor (details)
  • Learned baselines never learn a fault — no learning while an alarm is active, nor from a dry pipe or a motor-less current sensor
  • Freeze protection — pool temp below 4.5 °C → cyclic run (5 min ON / 10 min rest), also below 0 °C; a missing reading never ends it; suppressed if dry-run detected
  • No-flow stub — flow switch confirmed after settle; hardware-ready for future sensor
  • All alarms are latching — explicit acknowledgeAlarm() required

Filter maintenance

  • Filter status — clean / filling / backwash needed, from the pressure rise above the clean-filter pressure (details)
  • Clean pressure learned automatically on the first run; one call after each backwash re-learns it

Engineering

  • 577 B SRAM on Arduino Uno (example 01) — fits comfortably in 2 KB
  • 32 boolean flags / small modes packed into 4 bytes; all string literals in flash (F() macro)
  • EEPROM: 15 bytes, magic + version + checksum validation, persists target, clean pressure and settings
  • Zero delay() calls — every path returns within one loop() iteration
  • Designed to integrate with APADOSE and APALCDGUI via callback bridges — no coupling

Installation

Arduino IDE: Sketch → Include Library → Add .ZIP Library → select the APAPUMP folder.

PlatformIO:

lib_deps =
    https://github.com/apadevices/APAPUMP

What It Does

APAPUMP controls a pool filtration pump and up to three follower devices (UVC lamp, AUX device or heat pump, solar valve) through a PCF8574AT I2C relay expander or direct Arduino output pins. Each call to update() in your loop() advances the state machine, checks every safety guard in priority order, and fires alarm callbacks when something is wrong — all without blocking.

Out of the box, the zero-arg constructor targets the APA Devices HMI board v1.0: PCF8574AT at 0x3C with pump on P0, UVC on P1, AUX on P2, and solar valve on P3. Every optional feature is disabled by default and activated with one method call.


How It Works

State machine

                                ┌──────────────────────────────────┐
                                │           pump.begin()           │
                                ▼                                  │
                             [ IDLE ]                              │
                                │                                  │
                   _shouldPumpRun() = true                         │
                   min OFF time OK (60 s)                          │
                                │                                  │
                          [ STARTING ]                             │
                                │                                  │
                   UVC pre-delay (default 5 s)                     │
                                │                                  │
                          [ RUNNING ] ◄── safety alarms checked:   │
                                │         current · pressure ·     │
                                │         flow · freeze            │
                   _shouldPumpRun() = false                        │
                   min run time OK (300 s)                         │
                                │                                  │
                         [ STOPPING ]                              │
                                │                                  │
          AUX lead ──► pump OFF ──► UVC post-delay ────────────────┘
          (no AUX lead on FORCE_OFF or a pump alarm: AUX + pump OFF at once)

Guards that bypass min-run time: FORCE_ON and FORCE_OFF — manual mode suspends timing guards.

Stops without the AUX lead (since 1.3.1): FORCE_OFF and a latched pump alarm switch AUX and the pump off together — OFF means stop now, and a pump running dry or overloaded must not keep running for an after-run. Coming during a running lead, they cut it short. UVC still gets its post-delay.

Follower timing

Time →    0         5s         15s       [pump runs…]   Ts-30s    Ts      Ts+30s
          │          │          │                │        │         │        │
UVC:      ├──ON──────┼──────────┼────────────────┼────────┼─────────┼──OFF───┤
Pump:               ON──────────────────────────────────OFF
AUX:                           ON───────────────OFF
          ◄─ pre ──►◄──────────────── RUNNING ──────────►◄─ lead ─►◄─ post─►

Ts = moment the stop sequence begins. pre = enableUVC(preDelayS, …). lead = enableAux(…, stopLeadS). post = enableUVC(…, postDelayS). With FORCE_OFF or a latched pump alarm there is no lead: AUX and the pump go off at Ts (since 1.3.1).

Priority engine

Every update() tick calls the priority engine. The first rule that matches wins:

Priority Condition Result
P0 Collector > safety temp (default 50 °C), AUTO only, no pump alarm Pump ON + valve OPEN
P1 FORCE_OFF manual mode Pump OFF
P2 FORCE_ON manual mode Pump ON
P3 External request callback returns true Pump ON
P4 Freeze: pool temp < threshold AND water present Pump ON
P5a Solar wants to run: heating (hysteresis) or cooling Pump ON
P5b Schedule callback returns true (default SOLAR_WITH_SCHEDULE, or no solar) Pump ON
P5b' SOLAR_WITH_CATCHUP only: daily runtime < target (window OK) — replaces P5b Pump ON
— None of the above Pump OFF

Before 1.3.0, P0 also overrode FORCE_OFF. It no longer does: manual OFF usually means someone is working at the pump, and after a dry-run alarm there is no water to circulate. The collector has its own vent valve for overheating.

PCF relay layout (APA HMI board v1.0 defaults)

PCF8574AT at I2C address 0x3C
│
├─ P0 ── Pump relay              (always required)
├─ P1 ── UVC relay               (optional — enableUVC())
├─ P2 ── AUX relay               (optional — enableAux())
└─ P3 ── Solar valve relay       (optional — enableSolar(…, useValve=true))
│
├─ P4 ── Extension relay         (optional — setExtraOutput(4, on/off))
├─ P5 ── Extension relay         (optional — setExtraOutput(5, on/off))
├─ P6 ── Extension relay         (optional — setExtraOutput(6, on/off))
└─ P7 ── Extension relay         (optional — setExtraOutput(7, on/off))

The zero-arg constructor is active-low (the board's 74HC240 inverts): PCF LOW = relay ON. begin() writes all relays OFF immediately (0xFF), before any other code runs.


Quick Start

Minimal — APA HMI board defaults (zero wiring, zero config)

#include <Wire.h>
#include <APAPUMP.h>

ApaPump pump;              // PCF at 0x3C — pump=P0, uvc=P1, aux=P2, valve=P3

void setup() {
    Wire.begin();          // required for PCF mode — call before pump.begin()
    pump.begin();          // all relays OFF, EEPROM loaded
}

void loop() {
    pump.update();         // non-blocking — call every loop()
}

Alternative: direct GPIO

// Active-high relay (most modules)
ApaPump pump(RELAY_DIRECT, 7);               // pump on pin 7

// Active-low relay (some modules)
ApaPump pump(RELAY_DIRECT, 7);
pump.setActiveLow();             // call BEFORE pump.begin()

// Multiple relays, direct GPIO
ApaPump pump(RELAY_DIRECT, 7, 8, 9, 10);    // pump=7, uvc=8, aux=9, valve=10

Scheduled pump with alarm feedback

#include <Wire.h>
#include <APAPUMP.h>

ApaPump pump;

bool scheduleActive() {
    // return true when your RTC time falls inside a timer slot
    return false;  // replace with real logic
}

void onAlarm(PumpAlarm alarm) {
    if (alarm == PUMP_ALARM_NONE) return;   // alarm was cleared
    Serial.print(F("Pump alarm: "));
    switch (alarm) {
        case PUMP_ALARM_OVERCURRENT:   Serial.println(F("overcurrent"));   break;
        case PUMP_ALARM_LOW_PRESSURE:  Serial.println(F("dry run"));       break;
        case PUMP_ALARM_HIGH_PRESSURE: Serial.println(F("high pressure")); break;
        case PUMP_ALARM_NO_FLOW:       Serial.println(F("no flow"));       break;
        default: break;
    }
    // pump continues running — call pump.acknowledgeAlarm() when investigated
}

void setup() {
    Wire.begin();
    pump.begin(scheduleActive);             // schedule drives on/off
    pump.enableUVC(5, 30);                  // UVC: 5 s pre, 30 s post
    pump.enableAux(10, 30);                 // AUX: 10 s delay, 30 s lead
    pump.setPumpAlarmCallback(onAlarm);
}

void loop() { pump.update(); }

Manual Override

Force the pump on or off at any time. All timing guards and schedules are suspended:

pump.setManualMode(FORCE_ON);   // force pump ON  (e.g. vacuuming, winterising)
pump.setManualMode(FORCE_OFF);  // force pump OFF (e.g. plumbing, service)
pump.setManualMode(AUTO);       // return to automatic control

The solar valve closes immediately when entering FORCE_ON — operator gets full system pressure.

Auto-return options — pick one or both:

// Timeout: returns to AUTO after 60 minutes
ApaPump pump(RELAY_PCF, 0x3C, 0, 1, 2, 3, 60);   // 6th constructor parameter
pump.setManualTimeout(60);                           // or set at any time

// Midnight reset (requires setMidnightCallback())
pump.setManualAutoReset(true);

Note: solar overheat protection (P0) runs only in AUTO (since 1.3.0). In FORCE_OFF/FORCE_ON it is skipped — isSolarSafetyActive() still reports a hot collector so your sketch can warn.


Followers: UVC, AUX, Solar Valve

Each follower is independent and optional. Wire the relay to the corresponding PCF bit (or GPIO pin), then call the enable method:

// UVC lamp: ON 5 s before pump, OFF 30 s after pump stops
pump.enableUVC(5, 30);

// AUX device: ON 10 s after pump starts, OFF 30 s before pump stops (plain follower)
pump.enableAux(10, 30);

// Solar valve on P3 (or direct pin d): follows the solar demand
pump.enableSolar(absorberTempCb, poolTempCb, /*useValve=*/true, ...);

UVC pre-delay — when a pre-delay is configured, the pump enters STARTING state while UVC warms up. If the reason to start disappears during STARTING (e.g. schedule ends), the sequence is cancelled cleanly — UVC turns off and the pump never fires.


Solar Heating

By default (SOLAR_WITH_SCHEDULE) your schedule keeps driving the pump and solar adds extra runs: heating when the collector is warmer than the pool, cooling when the pool is above Max pool. During a scheduled run the valve opens whenever solar heating or cooling wants it, and closes again when not.

pump.setPoolTempCallback([]() { return poolTemp; });   // shared by solar, heater FULL
pump.enableSolar(
    []() { return collectorTemp; },   // collector (absorber) temperature, °C
    nullptr,                          // pool temp: nullptr = keep setPoolTempCallback()
    true,                             // useValve — first-boot default (SOLAR_VALVE / SOLAR_PUMP)
    8.0f,                             // startDelta: start when collector > pool + 8 °C
    3.0f,                             // stopDelta:  stop  when collector < pool + 3 °C
    32.0f,                            // maxPoolTemp — first-boot default, 0 = no limit
    2.0f,                             // coolDelta: cool when collector < pool - 2 °C
    60.0f                             // safetyTemp: overheat protection (AUTO only)
);
pump.setSolarDayNight([]() { return RTClib::now().unixtime(); }, 6, 21);   // heating 06:00-21:00

// From a menu (saved, survive a reboot):
pump.setSolarMode(SOLAR_OFF);         // or SOLAR_PUMP (no valve) / SOLAR_VALVE
pump.setSolarMaxPool(30);             // °C; 0 = no limit — no cooling AND no heating cap
  • Max pool is a cap: solar heating does not start at or above Max pool, and a running heating run ends once the pool reaches it (since 1.3.3; before, a running run continued until the collector cooled, so the pool could end above Max pool). It may start again below Max pool − APAPUMP_SOLAR_MAX_POOL_HYST_C (0.5 °C). Above Max pool cooling runs when the collector is coolDelta colder than the pool.
  • SOLAR_PUMP — no valve: solar only switches the filtration pump; the collector is always in the loop.
  • SOLAR_VALVE — a 3-way valve on P3. Without a valve relay it is stored as SOLAR_PUMP.
  • Valve settle: after every valve change the pressure checks and baseline learning pause for APAPUMP_VALVE_SETTLE_SEC (30 s) — air pushed out of the collector line must not trip a dry-run alarm.
  • 1.2.0 behaviour (solar is the only driver, the schedule only gives the daily target): pump.setSolarDrive(SOLAR_WITH_CATCHUP); — see Daily runtime.
  • Pump alarm: while a pump alarm is latched, solar asks for no extra runs at all (after a dry run there is no water to circulate). Your schedule still runs — stop the pump on an alarm in your sketch.
  • Status: isSolarRunning(), isSolarValveOpen(), isSolarSafetyActive() (collector above safetyTemp, reported in every mode), isSolarSensorOk().

Invalid temperatures

A temperature is used only if it is between APAPUMP_TEMP_MIN_C (−20) and APAPUMP_TEMP_MAX_C (100 °C), and not exactly 85.0 (DS18B20 power-on value) or −1.0 (the "not ready" value of APAPUMP ≤ 1.2.0). Return −127.0f from a callback while a sensor is not ready. On an invalid collector or pool reading, solar does nothing at all — no heating, no cooling, no overheat protection — and isSolarSensorOk() is false (status "Solar sensor fault"). Before 1.3.0 a missing collector sensor (−127) made cooling run nonstop, and a missing pool sensor made heating run all day. A pool temperature callback is now required for solar.

Day/night gate — why it exists

setSolarDayNight() allows heating only between the two hours; cooling is temperature-only, day or night. The gate is a safety net for a collector sensor in the wrong place: mounted on a pipe near the pump room instead of on the absorber (or its outlet), it can read "warmer than the pool" in the evening or at night. Solar would then push water through a cold absorber — cooling the pool. Use wide hours (e.g. 06–21): a dark roof often still gains heat after 20:00. The hours need the RTC on local time.

Overheat protection

Collector above safetyTemp → the pump runs and the valve opens, but only in AUTO and never while a pump alarm is latched. Manual OFF usually means someone is working at the pump; after a dry run there is no water to circulate. Pool collectors have their own vent valve. Choose safetyTemp above the pool temperatures you expect — every overheat run pushes hot water into the pool, even above Max pool.

Solar hysteresis

Absorber temp
     │
     │                     START threshold = pool + startDelta
─────┼──────────────────────────────────────────────────────
     │   ← pump ON                               pump ON →
     │
─────┼──────────────────────────────────────────────────────
     │                     STOP threshold = pool + stopDelta
     │

The gap between start and stop thresholds prevents rapid on/off cycling when temperature hovers near the boundary. Increase startDelta − stopDelta for wider hysteresis.


Heater (heat pump) on the AUX relay

pump.enableAux(10, 120);              // on 10 s after the pump; pump runs 120 s after it (after-run)
if (!pump.hasSavedSettings()) pump.setAuxMode(HEATER_SIMPLE);   // first boot only — saved
AuxMode AUX relay
AUX_DISABLED never on
AUX_FOLLOWER on/off with the pump, exactly as before 1.3.0 (ozone etc.) — first-boot default of enableAux()
HEATER_SIMPLE allowed while the pump runs; the heat pump's own thermostat regulates
HEATER_FULL the library is the thermostat: on below setHeaterTarget() − 1.0 °C, off at the target (15–40 °C, default 28)

In both heater modes the AUX relay is on only while all of these hold: the pump runs (past the start delay) · no pump alarm (no flow = no heating) · solar is not heating, could not heat right now (collector above pool + startDelta, inside the day gate) and the collector is not over-hot (solar first) · the permit callback allows it (setHeaterPermitCallback(), e.g. a cheap-tariff input) · the pool is not above Max pool. HEATER_FULL also needs a valid pool reading. A 10-minute minimum ON and OFF time (APAPUMP_HEATER_MIN_ON_SEC / _MIN_OFF_SEC) protects the compressor — also after power-up, so the heater waits 10 min after a (re)boot; a pump alarm, a pump stop or running overheat protection (AUTO, collector above the safety temperature — since 1.3.2) always switch it off at once. When normal solar heating takes over, a running heat pump finishes its minimum ON time. The heater never asks for extra pump runs — it heats during your filtration schedule. When the heater was already off, the pump stops without the after-run. FORCE_OFF and a pump alarm also stop the pump without the after-run (since 1.3.1) — the heat pump's own flow switch protects it then. isHeaterOn() reports the relay.

In HEATER_FULL set the heat pump's own thermostat to its maximum — otherwise the lower of the two settings wins.

Relay rule: the AUX relay switches the heat pump's remote ON/OFF input (a few mA) or a fused contactor coil with suppression (RC snubber / varistor) — never the compressor or a heating element directly.


Saved settings

The library saves only what an owner or installer changes, so it survives a reboot: solar mode, Max pool, AUX/heater mode, heater target, pressure monitoring ON/OFF (plus, as before, the daily target, minimum run time and clean-filter pressure). Constants — start/stop/cool deltas, safety temperature, day gate hours, drive model, timings — are not saved: pass them in setup() every boot.

enableSolar() / enableAux() give first-boot defaults only; once saved values exist they win. A saved mode never activates hardware by itself: solar needs enableSolar() and the AUX relay enableAux() (or setAuxMode()) in every boot. To apply your own first-boot defaults without overwriting the owner's choice on every boot:

if (!pump.hasSavedSettings()) {       // true after the first boot with this version
    pump.setSolarMode(SOLAR_OFF);     // e.g. a product shipped with solar off
}

Saved setters write the EEPROM only after begin(). Upgrading from 1.2.0 resets the EEPROM once (layout version 2): the clean-filter pressure and daily counters are learned again.


Daily Runtime Target and Catch-Up

// Option A: fixed target (user sets it once)
pump.setDailyTarget(360);                   // run 6 hours per day

// Option B: use the APALCDGUI timer sum as the target
pump.begin(scheduleActive, nullptr,
           []() { return gui.getTimerTotalMinutes(); });

// Query progress
uint16_t ran = pump.getDailyRuntimeMinutes();
bool     met = pump.isDailyTargetMet();

Catch-up is used only with setSolarDrive(SOLAR_WITH_CATCHUP) (the 1.2.0 model, where solar is the only driver). It runs as soon as today's runtime is below the target — from midnight, or from the start of the catch-up window:

// Optional: limit catch-up to daytime hours (requires setMidnightCallback)
pump.setCatchupWindow(8, 20);   // catch-up only between 08:00 and 20:00

Safety Alarms

All alarms are latching — the pump does not stop automatically (your sketch decides the action). Call acknowledgeAlarm() after investigation to clear.

Alarm Triggers when Requires
PUMP_ALARM_OVERCURRENT current > learned baseline × 1.5 (details) setCurrentCallback()
PUMP_ALARM_LOW_PRESSURE pressure below 40% of EMA baseline (dry-run) enablePressure()
PUMP_ALARM_HIGH_PRESSURE pressure > maxPressure (absolute) enablePressure() with maxPressure > 0
PUMP_ALARM_HIGH_PRESSURE sudden rise > baseline × (1 + peakPct %) setPressurePeakAlarm() (off by default)
PUMP_ALARM_NO_FLOW flow switch reports no flow after 30 s settle setFlowCallback()

Alarm checks run every update() once the pump has run 30 s; overcurrent is checked with each 10 s current sample. While an alarm is active, nothing is learned — a dry run or an overcurrent never becomes the new "normal".

The sudden-rise alarm does not detect a dirty filter. Its baseline follows slow changes within minutes, so weeks of clogging never trip it — that is what filter status is for. It catches fast changes such as a valve closed while the pump runs. Turning a multiport valve (e.g. to backwash) while the pump runs can trip it, which is why it is off by default.

Stopping the pump on an alarm (recommended)

A pump that keeps running dry or overloaded can be destroyed within minutes, so most sketches should stop it. Keep it stopped while the alarm is active — setManualMode(FORCE_OFF) alone returns to AUTO after the manual timeout and would restart the pump, and the library skips its checks while an alarm is active:

void loop() {
    pump.update();
    if (pump.getAlarm() != PUMP_ALARM_NONE && pump.getManualMode() != FORCE_OFF)
        pump.setManualMode(FORCE_OFF);   // re-asserted until the operator acknowledges
}

// Operator has checked the pump (HMI button, Serial command, ...):
pump.acknowledgeAlarm();
pump.setManualMode(AUTO);

Alarm callback pattern:

pump.setPumpAlarmCallback([](PumpAlarm alarm) {
    if (alarm == PUMP_ALARM_NONE) {
        // alarm was acknowledged — update LCD, clear indicator
        gui.cancelActiveAlert();
        return;
    }
    // alarm fired — notify operator
    gui.postActiveAlert(F("Pump alarm!"), F("Check equipment"),
                        ALERT_CRITICAL, []() { pump.acknowledgeAlarm(); });
});

Wiring a buzzer or alarm output

The alarm callback is the right place to drive any physical indicator — buzzer, LED, relay. No extra library method needed.

Direct GPIO (no APASENSE):

pump.setPumpAlarmCallback([](PumpAlarm alarm) {
    bool active = (alarm != PUMP_ALARM_NONE);
    digitalWrite(5, active ? HIGH : LOW);   // buzzer on pin 5
});

With APASENSE (v1.1.0+, recommended for APA hardware):

pump.setPumpAlarmCallback([](PumpAlarm alarm) {
    bool active = (alarm != PUMP_ALARM_NONE);
    adc.setLed(0, active);                      // LED0 = PCF P4
    if (active) adc.alert(BUZZER_ALARM, true);  // repeating alarm pattern
    else         adc.stopAlert();               // silence when alarm clears
});

Tip: APASENSE owns the PCF expander LEDs and buzzer. alert(BUZZER_ALARM, true) plays a repeating triple-beep until stopAlert() is called — no delay() or manual timer needed.

Dry-run protection

When enablePressure() is registered, APAPUMP builds a dual pressure baseline (EMA): one for normal running, one for when the solar valve is open (higher pressure expected due to absorber resistance). One sample is taken every 10 s once the pump has run 30 s; after 5 samples the baseline is ready and PUMP_ALARM_LOW_PRESSURE fires when pressure drops below 40 % of it.

Before the baseline is ready, an absolute minimum of 0.1 bar (APAPUMP_PRESSURE_ABS_MIN) is used. Readings below 0.1 bar are never learned — a pump running dry cannot teach itself that "no pressure" is normal.

Pressure sensor optional

Not every installation has a pressure sensor (small garden pools often don't). Register the sensor once with enablePressure(), then switch monitoring on or off at any time — e.g. from an installer menu. Since 1.3.0 the library saves the choice (a saved OFF also wins over the next boot's enablePressure()), so call it only when the installer changes it:

pump.enablePressure([]() { return adc.getPressure(); }, 2.5f);
pump.setPressureEnabled(false);   // from the menu — saved; OFF: no pressure checks at all

With pressure off there is no dry-run, no high-pressure alarm and no filter status — the pump then has no protection against running dry. Without a sensor, leaving it on is harmless (a sensor that never delivers a valid reading keeps every pressure check inactive), but an explicit OFF also ignores a disconnected input that floats to a plausible value. Switching off clears the last reading and the learned baselines; switching on re-learns them (~80 s of running). The stored clean-filter pressure is kept.

Filter status — when to backwash

A sand or cartridge filter clogs slowly, and the pressure in front of it rises. getFilterStatus() compares the running pressure with the pressure measured when the filter was clean:

Status Rise above the clean pressure Example (clean = 1.0 bar)
FILTER_CLEAN below 0.4 bar below 1.4 bar
FILTER_FILLING 0.4 bar or more 1.4 bar or more — backwash soon
FILTER_BACKWASH_NEEDED 0.8 bar or more 1.8 bar or more — backwash now
FILTER_UNKNOWN no clean pressure or no baseline yet first ~80 s of running after each boot

The clean pressure is learned for you. On the first run after installation (pump running, solar valve closed, at least 0.1 bar) the library takes its first stable pressure (~80 s of running) as the clean pressure and saves it to EEPROM. Every pool's pipework gives a different normal pressure — this way the limits follow your pool, not a fixed number.

After every backwash call learnCleanPressure() once (e.g. from an HMI button). It clears the stored value and learns the new clean pressure during the next ~80 s of running — if the pump is off, it simply waits for the next run. It never copies a single reading, so a spike or a stopped pump cannot be learned by mistake.

pump.enablePressure([]() { return adc.getPressure(); }, 2.5f);

switch (pump.getFilterStatus()) {
    case FILTER_FILLING:         /* show "backwash soon" */            break;
    case FILTER_BACKWASH_NEEDED: /* show "backwash filter + LEARN" */  break;
    default: break;
}
// after backwashing:
pump.learnCleanPressure();
  • It is a status, not an alarm — backwashing is maintenance, not an emergency. It keeps its value while the pump is stopped.
  • The limits are household-pool values. Change them with setFilterThresholds(warn, backwash) at runtime, or build_flags = -DAPAPUMP_FILTER_WARN_DELTA=0.5f -DAPAPUMP_FILTER_BACKWASH_DELTA=1.0f.
  • setCleanPressure(bar) sets the clean pressure by hand; setCleanPressure(0) forgets it (the current baseline is then taken as clean).
  • Keep maxPressure in enablePressure() above the backwash level and at or below the filter's rated maximum (often 2.5 bar for household sand filters — check the label).

Overcurrent protection

setCurrentCallback() gives APAPUMP the pump's current in amps (APASENSE: adc.getCurrent()). A current well above normal means the motor is struggling: a blocked or jammed impeller, failing bearings, or a motor winding fault.

How it works

  1. Learns the pump's own normal current — no pump rating to enter. A 0.5 kW and a 1.5 kW pump each learn their own value.
  2. One sample every 10 s once the pump has run 30 s (motor start-up current is ignored).
  3. After 5 samples (~80 s of running) the baseline is ready and the alarm arms.
  4. PUMP_ALARM_OVERCURRENT fires when a sample exceeds 1.5 × the baseline. Checked every 10 s, so a fault is caught within 10 s.
  5. The baseline adapts slowly to normal changes (weight 5 % per sample) and is kept across pump cycles.

What it does not do

  • It does not stop the pump by itself — see Stopping the pump on an alarm.
  • It does not detect a dry run (a dry pump draws less current) — that is the pressure sensor's job.
  • It is not a replacement for the motor's own thermal protection or the circuit breaker. It warns early; the breaker protects the wiring.

Direct drive vs. external contactor — check how your pump is wired:

Wiring What passes the current sensor Overcurrent protection
Pump powered directly through the board's relay the pump's current (typically 2–8 A) active
Board relay only switches an external contactor in the electrical box only the contactor's coil (well under 0.5 A) silent — no alarms, no false alarms

Safety: switching the pump through an external contactor (rated for motor loads) is always recommended over connecting it directly to a controller relay. Small board relays are often not rated for a motor's start-up current.

Readings below 0.5 A (APAPUMP_CURRENT_MIN_A) are ignored: they are not a motor, just sensor noise or a contactor coil. So with a contactor the feature switches itself off safely — nothing to configure. With a contactor, pressure monitoring (dry run, high pressure, filter status) is the pump's protection; use a motor protection switch in the electrical box for the motor itself.

Good to know

  • The baseline lives in RAM: after each boot it is re-learned during the first ~80 s of running, with no overcurrent alarm during that time.
  • Nothing is learned while an alarm is active, so an overload never raises its own threshold.
  • After replacing or servicing the pump, call resetCurrentBaseline() so the new motor's current is learned.
  • A very small pump (under ~0.5 A): lower the floor with build_flags = -DAPAPUMP_CURRENT_MIN_A=0.3f.

Freeze protection

pump.enableFreezeProtection(
    []() { return adc.getPoolTemp(); },   // pool/pipe temperature
    4.5f                                  // threshold in °C (default)
);

When pool temperature drops below the threshold, the pump cycles to prevent pipes from freezing: runs for APAPUMP_FREEZE_ON_SEC (default 5 min), rests for APAPUMP_FREEZE_OFF_SEC (default 10 min), and repeats until a valid reading reaches threshold + APAPUMP_FREEZE_HYST_C (1.0 °C). Readings below 0 °C are valid (before 1.3.0 they were ignored, so protection was off exactly when freezing). An invalid reading (−127, −1.0, 85.0) never ends an active protection — if the sensor is lost while it is active, the cycles go on until a valid reading returns (fail-safe in frost). Both durations are overridable via build_flags. Dry-run interlock: if the pressure sensor is enabled, calibrated, and indicates no water in the pipes (pressure near zero), freeze protection is suppressed — forcing the pump without water would burn the motor.


Integrating with APADOSE and APALCDGUI

APAPUMP, APADOSE, and APALCDGUI are independent libraries — your sketch is the bridge. No library knows about the others.

Bridge: APALCDGUI timer → APAPUMP schedule

// In begin(): pass a lambda that reads the timer state from the GUI
pump.begin(
    []() {
        // true inside any timer slot; isTimerActive() also handles slots across midnight
        return gui.isTimerActive(rtcHour * 60 + rtcMinute);
    },
    nullptr,
    []() { return gui.getTimerTotalMinutes(); }  // daily target from timer sum
);

Bridge: APADOSE post-shock → APAPUMP

// Keep the pump running during a shock and for 4 hours after it, to circulate the
// chlorine (a schedule slot ending mid-shock would otherwise stop the pump and
// APADOSE would abort the shock). Uses the externalRequestCb — no new API needed.
// Elapsed-time check, so it stays correct when millis() wraps after ~49 days.

const uint32_t POST_SHOCK_MS = 4UL * 3600UL * 1000UL;
uint32_t postShockEndMs = 0;   // 0 = no post-shock window

bool postShockWantsPump() {
    if (dose1.isShockActive()) {
        postShockEndMs = millis() | 1;   // |1: never 0, the "no window" marker
        return true;
    }
    if (postShockEndMs == 0) return false;
    if (millis() - postShockEndMs < POST_SHOCK_MS) return true;
    postShockEndMs = 0;
    return false;
}

pump.begin(scheduleCb, postShockWantsPump);

Bridge: pump manual mode → APALCDGUI status indicator

// Show [M] in the LCD corner whenever the pump is in manual mode
pump.setStatusCallback([](const __FlashStringHelper* msg) {
    if (pump.getManualMode() != AUTO) gui.setStatusIndicator('M');
    else                              gui.clearStatusIndicator();
    // Also forward the status text to a scrolling message area
    Serial.println(msg);
});

Bridge: APASENSE → APAPUMP (pressure and current)

// Order: adc.begin() BEFORE pump.begin() — pressure auto-zeros on first pump stop.
// pressureCb returns -1.0f while APASENSE is uncalibrated — APAPUMP skips
// all pressure logic until a valid reading arrives.

adc.begin();    // zero-cal requires pump off — call first

pump.begin();
pump.enablePressure(
    []() { return adc.getPressure(); },    // -1.0f until calibrated
    2.5f                                   // alarm limit = filter's rated pressure (bar)
);
pump.setCurrentCallback([]() { return adc.getCurrent(); });   // amps; silent below 0.5 A

// Bridge: tell APASENSE when pump state changes so it can re-zero on pump stop
pump.setPumpStateCallback([](bool on) { adc.onPumpState(on); });

Examples

Sketch Level Description
examples/01_minimal/ Basic PCF or GPIO, manual override via Serial, all three constructor options
examples/02_scheduler/ Intermediate APALCDGUI timer schedule, UVC + AUX followers, alarm → active alert bridge
examples/03_solar_freeze/ Advanced Solar + valve, heat pump (HEATER_SIMPLE), freeze protection, pressure + current safety, filter status, pump stopped on alarm, APADOSE post-shock bridge
examples/04_hardware_test/ Bench Interactive relay/sensor test on the APA HMI board (LCD menu) — uses 93 % of an Uno's flash
examples/05_solar_heater/ Intermediate Schedule + solar + heat pump in a few lines; first-boot defaults with hasSavedSettings()

Platform Verification

Compiled with the 01_minimal example. Zero errors, zero library warnings on all platforms.

Platform Board RAM used RAM total Flash used Flash total
Arduino Mega 2560 ATmega2560 577 B 8 192 B (7.0%) 13 420 B 253 952 B (5.3%)
Arduino Uno ATmega328P 577 B 2 048 B (28.2%) 12 658 B 32 256 B (39.2%)
ESP32 DevKit ESP32 22 040 B 327 680 B (6.7%) 292 113 B 1 310 720 B (22.3%)
ESP8266 D1 Mini ESP8266 28 868 B 81 920 B (35.2%) 275 539 B 1 044 464 B (26.4%)
STM32 Bluepill STM32F103C8 2 644 B 20 480 B (12.9%) 27 096 B 65 536 B (41.3%)

All five examples build on all five platforms (1.3.0). Against 1.2.0: +13–16 B RAM, about +1.5 KB flash. 1.3.1 (stop-sequence patch) was built on the Mega only: +0 B RAM, +32 B flash. 1.3.2 (heater cut by overheat protection) was built on AVR (Mega, Uno) only: +0 B RAM, +10 B flash. 1.3.3 (Max pool ends a running heating run) was built on AVR (Mega, Uno) only: +0 B RAM, +54 B flash.

The Uno row uses 28.2% RAM — that is the library with all Phase 2 features registered in the example. A minimal sketch (no solar, no pressure, no freeze) sits below 20%. ESP32 and ESP8266 totals include the full Arduino framework regardless of use.


EEPROM Layout

APAPUMP reserves 15 bytes starting at APAPUMP_EEPROM_ADDR (default 520) — layout version 2 since 1.3.0 (12 bytes before).

Field map

Address Bytes Field Saved when
520 2 Magic 0xA55A — validity marker
522 1 Config version — mismatch resets all fields to defaults
523 2 Daily target (minutes) setDailyTarget()
525 2 Yesterday's runtime (minutes) Midnight rollover (once per day)
527 2 Minimum run time (seconds) setMinRunTime()
529 2 Clean pressure × 100 (bar; 0 = not learned) automatic first learn, learnCleanPressure(), setCleanPressure()
531 1 Settings: bit 0 pressure ON, bits 1–2 SolarMode, bits 3–4 AuxMode setPressureEnabled(), setSolarMode(), setAuxMode()
532 1 Max pool (°C, 0 = no limit) setSolarMaxPool()
533 1 Heater target (°C) setHeaterTarget()
534 1 Checksum (byte sum of bytes 520–533) — corruption guard

Write protection and EEPROM lifespan

_saveEEPROM() writes the full 15-byte struct, but a physical write only occurs when a byte has actually changed:

  • AVR (Uno/Mega): EEPROM.put() calls EEPROM.update() per byte — reads first, writes only if value differs.
  • ESP32/ESP8266: EEPROM.put() updates a RAM buffer; EEPROM.commit() compares the buffer to flash before writing — no flash write if content unchanged.
  • STM32: EEPROM emulation with compare-before-write.

Practical write frequency (worst case on a running system):

Event Max frequency Cycles used at 100 k limit
Midnight rollover 1 per day 100 k days ≈ 273 years
Clean pressure (first learn, learnCleanPressure()) After install / after each backwash Negligible
setMinRunTime() from setup() 0 physical writes if value unchanged None
First boot / corruption recovery Once 1 cycle

Corruption recovery: the checksum is verified on every begin(). If power fails mid-write and data is corrupted, the mismatch is detected on the next boot, factory defaults are loaded, and a clean struct is written.

Override base address

; platformio.ini — build_flags reach both your sketch and the library's own .cpp
build_flags = -DAPAPUMP_EEPROM_ADDR=535

APA EEPROM address map

All ranges across the APA library suite — free blocks shown explicitly:

Range Bytes Status Owner
0–127 128 free —
128–177 50 used APAPHX2_ADS1115 (sensor calibration)
178–188 11 free —
189–191 3 used APADOSE global (pool volume, dead-band)
192–291 100 used APADOSE per-pump config (25 bytes × up to 4 instances)
292–499 208 free —
500–501 2 used APALCDGUI brightness
502–508 7 used APALCDGUI timer slots (default 3 slots)
509–519 11 free — gap before APAPUMP ¹
520–534 15 used APAPUMP (12 bytes before 1.3.0)
535–581 47 free — APAPUMP expansion reserve
582–587 6 used APASENSE (pressure zero)
588– — free —

¹ When APA_LCD_MAX_TIMERS=6 the timer block extends to 514, leaving a 5-byte gap (515–519) before APAPUMP. This gap is intentional — do not place anything in 515–519 to keep the gap safe regardless of timer configuration.


License

Dual license — see LICENSE file for full terms.

Use License
Personal, private, educational, hobby Free — no charge, no paperwork
Commercial (products, services, OEM) Separate written license required

Commercial use includes selling or distributing hardware with this software, providing paid pool automation services, or integrating it into any revenue-generating product or system.