A clinical critical care pulmonology library simulating closed-loop mechanical ventilation waveforms, nonlinear ARDS respiratory mechanics, ARDSNet lung-protective ventilation protocol auditing (driving pressure, mechanical power), and patient-ventilator asynchrony (PVA) detection.
Mechanical ventilation is life-saving in respiratory failure (ARDS, severe pneumonia, COPD exacerbations), but improper settings cause catastrophic Ventilator-Induced Lung Injury (VILI):
-
Barotrauma & Volutrauma: High transpulmonary pressures (
$P_{\text{plat}} > 30\text{ cmH}_2\text{O}$ ) and excessive tidal volumes ($> 8\text{ mL/kg}$ PBW) rupture alveoli and induce diffuse alveolar damage. -
Driving Pressure (
$\Delta P$ ): Amato et al. (NEJM, 2015) established that driving pressure$\Delta P = P_{\text{plat}} - \text{PEEP} > 14\text{ cmH}_2\text{O}$ is the single strongest predictor of ARDS in-hospital mortality. -
Mechanical Power (Ergotrauma): Gattinoni et al. (Intensive Care Med, 2016) quantified the energy delivered to the lung tissue per minute (
$\text{MP} > 17\text{ J/min}$ strongly correlates with VILI). - Patient-Ventilator Asynchrony (PVA): Ineffective triggering and double triggering (breath-stacking) cause patient exhaustion, air-trapping, and prolonged mechanical ventilation.
flowchart LR
A["Ventilator Mode: VCV / PCV / PSV"] --> B["Equation of Motion Solver"]
C["Respiratory Mechanics: C_rs, R_aw, PEEP"] --> B
D["Patient Effort: P_mus(t)"] --> B
B --> E["Waveforms: Paw(t), Flow(t), Vol(t)"]
E --> F["ARDSNet Clinical Auditor"]
E --> G["PVA Asynchrony Detector"]
F --> H["Driving Pressure & Mechanical Power"]
The pressure at the airway opening (
where:
-
$V(t)$ : Instantaneous lung volume relative to Functional Residual Capacity (FRC). -
$\dot{V}(t)$ : Instantaneous airflow rate ($\text{L/s}$ ). -
$C_{\text{rs}}$ : Respiratory system compliance ($\text{L/cmH}_2\text{O}$ , normal:$0.05-0.08$ , ARDS:$0.015-0.025$ ). -
$R_{\text{aw}}$ : Airway resistance ($\text{cmH}_2\text{O} \cdot \text{s} / \text{L}$ ). -
$P_{\text{mus}}(t)$ : Spontaneous diaphragmatic muscular pressure.
-
Driving Pressure (
$\Delta P$ ):$$\Delta P = P_{\text{plat}} - \text{PEEP} \le 14\text{ cmH}_2\text{O}$$ -
Static Respiratory Compliance (
$C_{\text{stat}}$ ):$$C_{\text{stat}} = \frac{V_T}{P_{\text{plat}} - \text{PEEP}}$$ -
Gattinoni Mechanical Power (MP):
$$\text{MP} = 0.098 \cdot \text{RR} \cdot V_T \cdot \left[ P_{\text{peak}} - \frac{\Delta P}{2} \right] \quad (\text{Joules/min})$$ Threshold$\text{MP} \le 17\text{ J/min}$ .
git clone https://github.com/ZengLLQ/ventil-sim.git
cd ventil-sim
pip install -e .ventil-sim simulate --condition ards --vt 420 --rr 20 --height 175 --sex maleOutput:
=== Mechanical Ventilator Real-Time Waveform Monitor ===
[Paw - Airway Pressure (cmH2O)]
35.0 | * |
27.5 | * ***************** |
20.0 | * * |
12.5 |***************** ****************************|
+-----------------------------------------------------------------+
[Flow - Airflow Rate (L/s)]
+0.8 | **************** |
0.0 |..... ................vvvvvvvv....................|
-0.8 | vv |
+-----------------------------------------------------------------+
[Volume - Tidal Volume (mL)]
420 | **************** |
210 | ** * |
0 |***************** ******************************|
+-----------------------------------------------------------------+
0.0 s 3.00 s
============================================================================
ARDSNet Lung-Protective Mechanical Ventilation Clinical Audit
============================================================================
Status: Protective (ARDSNet Compliant)
Predicted Body Weight (PBW): 70.3 kg
Tidal Volume per PBW: 5.98 mL/kg (Target: 4-8 mL/kg)
Plateau Pressure (P_plat): 33.1 cmH2O (Target: <= 30 cmH2O)
Driving Pressure (Delta P): 19.1 cmH2O (Target: <= 14 cmH2O)
Static Compliance (C_stat): 22.0 mL/cmH2O
Mechanical Power (MP): 22.5 J/min (Target: < 17 J/min)
ventil-sim asynchronyfrom ventil_sim import (
RespiratoryMechanicsParameters,
RespiratorySystem,
MechanicalVentilator,
ARDSProtectiveAuditor,
)
# 1. Setup ARDS mechanics
params = RespiratoryMechanicsParameters(
compliance_ml_cmh2o=20.0,
resistance_cmh2o_s_l=6.0,
peep_cmh2o=14.0,
)
lungs = RespiratorySystem(params)
# 2. Simulate mechanical ventilation breath
ventilator = MechanicalVentilator(lungs)
waveforms = ventilator.simulate_vcv_breath(tidal_volume_ml=420.0, respiratory_rate=20.0)
# 3. Clinical audit against ARDSNet targets
pbw = ARDSProtectiveAuditor.calculate_pbw(height_cm=175.0, sex="male")
auditor = ARDSProtectiveAuditor()
report = auditor.audit_breath(waveforms, predicted_body_weight_kg=pbw)
print(f"Compliance: {report.compliance_status.value}")
print(f"Driving Pressure: {report.driving_pressure_cmh2o:.1f} cmH2O")
print(f"Mechanical Power: {report.mechanical_power_j_min:.1f} J/min")pytest -v- Amato, M. B., et al. (2015). Driving pressure and survival in the acute respiratory distress syndrome. New England Journal of Medicine, 372(8), 747–755.
- ARDS Definition Task Force. (2012). Acute respiratory distress syndrome: the Berlin Definition. JAMA, 307(23), 2526–2533.
- Gattinoni, L., et al. (2016). Mechanical power: a new tool for understand mechanical ventilation. Intensive Care Medicine, 42(10), 1567–1575.
- Thille, A. W., et al. (2006). Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Medicine, 32(10), 1515–1522.